There is an allowance however for variations in the handrail size for every 1 2 of additional perimeter dimension over 4 you may subtract 1 8 from the clearance.
Wall mounted handrail bracket spacing code.
Irc 2003 1 1 2 inch 38mm minimum between wall and the handrail.
Typical code requirements state that the top rail must be able to withstand a 200lb outward force.
F the mounting of handrails shall be such that the completed structure is capable of withstanding a load of at least 200 pounds applied in any direction at any point on the rail.
Use internal couplings type 18 7 to maintain continuity.
In hollow wall applications handrail brackets must be fastened to wood studs or appropriate blocking must be provided to meet structural requirements.
Codes also generally require that there be a 1 1 2 clearance between the underside of the handrail and any obstruction including the horizontal bracket arm.
Ansi a117 1 1 1 2 inch minimum.
The spacing of brackets shall not exceed 8 feet.
Handrail brackets or pickets attached to the bottom of the handrail that do not project horizontally beyond the sides of the handrail within 1 5 of the bottom of the handrail shall not be considered obstructions 9.
Ibc 1014 4 key exception.
Ibc 2003 clear space between a handrail and a wall or other surface shall be a minimum of 1 50 inches 38mm.
A handrail and a wall or other surface adjacent to the handrail shall be free of any sharp or abrasive elements.
Place the short cut returns from step 2 against the two ends of the handrail so the returns turn the handrail end toward.
Handrail must be continuous.
The spacing of brackets shall not exceed 8 feet.
A handrail or grab bar and any wall or other surface adjacent to it needs to be free of anything sharp or abrasive.
Clear space between a handrail and a wall or other surface shall be not less than 1 5.
Ibc 2000 1 1 2 inch minimum.
For example the minimum hand clearance between the railing and the wall that it is mounted on is 1 1 2 inches.
Mount the wooden handrail with screws from the bracket s assembly kit.
Yet if the railing is pushed out too far there is the risk of violating another section of code that provides for 27 inches of walking width between the two railings of a double railing staircase.
Cast handrail bracket with tapped hole mounted with hanger bolt and lag screw expansion shield.
E handrails projecting from a wall shall have a space of not less than 1 1 2 inches between the wall and the handrail.
For the typical guard rail you want unsupported spans no greater than 8 in most cases.
In other words it can t be wobbly and unstable.